Journal of Exercise Science & Fitness
Volume 7, Issue 2, Supplement , Pages S51-S60, 2009

Physiological, Biochemical and Mechanical Issues Relating to Resistive Force Selection During High-intensity Cycle Ergometer Exercise

  • Julien Steven Baker

      Affiliations

    • Health and Exercise Science Research Laboratory, School of Science, University of the West of Scotland, Hamilton Campus, SCOTLAND
    • Corresponding Author InformationCorresponding Author Julien Steven Baker, Health and Exercise Science Research Laboratory, School of Science, University of the West of Scotland, Hamilton Campus, ML3 OJB, SCOTLAND. Tel: (44) (0)1698 283100, Fax: (44) (0)1698 894404
  • ,
  • Non Eleri Thomas

      Affiliations

    • Centre for Child Research, School of Human Sciences, Swansea University, Singleton Park, Swansea, WALES
  • ,
  • Bruce Davies

      Affiliations

    • Health and Exercise Science Research Laboratory, School of Applied Science, University of Glamorgan, Pontypridd, WALES

High-intensity cycle ergometry of 30 seconds duration has been widely employed to assess indices of muscle performance during maximal exercise. Traditionally, the resistive force established for such a test is determined from total body mass (TBM) for a friction-loaded Monark cycle ergometer, i.e. 75 g·kg−1. More recent studies have shown that traditional forces may be too light to elicit maximal performances and that optimization protocols can produce higher peak power outputs. Conceptually, selecting the optimal resistive force according to TBM may not be the best approach. Fat-free mass or active muscle tissue may be a more preferable alternative. Because body mass, and not composition, is the most commonly used index to determine cycle ergometer resistive force, over-or underestimations in power calculations may occur. The aim of this paper is to outline friction-loaded cycle ergometer performance using resistive forces derived from TBM and fat-free mass, to quantify the upper body contribution to high-intensity cycle ergometry. A further aim is to outline mechanical issues related to cycle ergometer design and to quantify discrepancies in resistive force application.

Keywords:  high-intensity ergometer exercise , mechanical deformity , resistive force

No full text is available. To read the body of this article, please view the PDF online.

 

PII: S1728-869X(09)60023-X

doi:10.1016/S1728-869X(09)60023-X

Journal of Exercise Science & Fitness
Volume 7, Issue 2, Supplement , Pages S51-S60, 2009